GovBidFit database · SAM.gov sourceData refreshed September 20, 2026Official description stored

Sources Sought

The Data COUNTS� (Collect Data Once, Use Numerous Times)

Federal Sources Sought from HEALTH AND HUMAN SERVICES, DEPARTMENT OF for Maryland. Review the official description, buyer contacts, NAICS/PSC, set-aside,…

Solicitation75N95C26R00005
Notice typeSources Sought
PostedSeptember 1, 2026
Response deadlineOctober 1, 2026
Place of performanceBethesda, Maryland, 20817, USA
ClassificationPSC DA10
Set-asideNo Set aside used

OFFICIAL NOTICE CONTENT

Opportunity description

Stored from SAM.gov public data

Description This is a Request for Information (RFI). This is NOT a solicitation for proposals, proposal abstracts, or questions. The purpose of this RFI is to obtain knowledge and information for project planning purposes. The Government does not intend to award a contract on the basis of the RFI or otherwise pay for the information requested. Responses will be treated as information only and not as a proposal. The NIH seeks information on technologies and capabilities to further the objectives of the Data COUNTS program. The Data COUNTS� (Collect Data Once, Use Numerous Times) effort is built on collaboration between patients and advocates, government, health systems, technology companies, and the private sector. The Data COUNTS program enables the NIH�s Real-World Data initiative and will provide high quality, standardized data that is provenanced and available through approved access to the research community. The contemplated capability will initially perform requested and approved extraction from Healthcare Partner EMR systems and should be modular and extensible to other authorized source systems such as laboratory information systems, pharmacy information systems, picture archiving and communication systems, vendor-neutral archives, and specialty systems. The Data COUNTS program requires that source data, and source provenance metadata, permissions, and source ontology fields will be preserved without modification or loss. This program will not create or standardize ontology mappings. Technical Requirements of Interest: Address availability and technologies that enable the following features: A durable, Healthcare Partner Leave Behind Technology capability that remains at the Healthcare Partner site after contract completion and can be operated by trained staff without ongoing involvement. The technology should be available and free for use by Healthcare Partners while in the Data COUNTS program. Describe any installation and configuration documentation, operational runbooks, site-controlled credential-transfer procedures, documented dependencies, major-release update procedures, and training that enable independent site operations. Deep query for approved extraction from Healthcare Partner electronic medical records (EMR) systems and other authorized source systems. Capture timestamps and provenance for all data at extraction and maintain an immutable provenance chain. The architecture consumes a machine-readable, version-controlled, authorized, and approved Data Request Specification defining cohort logic, requested source systems, data domains and fields, date range, full or incremental extraction mode, refresh cadence, and applicable authorization and permission rules. Describe how the solution validates data availability against the specification, identifies unavailable or ambiguous fields, avoids silent substitutions, associates the request identifier with each batch and output, and supports reproducible reruns when source data have not changed. An initial automated data quality check validating completeness, uniqueness, data types, date sequencing, and records-per-patient. All anomalies must be reported before any permitted corrections are applied. Sourced data will not be modified De-identification per 45 CFR �164.514(b): remove all 18 direct identifiers; document a consistent de-identification pathway; and apply a per-patient date-shifting specification that preserves temporal order. Privacy Preserving Record Linkage (PPRL) tokenization capabilities for cross-site linkage using an approved, on-premises within the institutional trust boundary PPRL platform that generates consistent, irreversible patient tokens. Describe validation and Healthcare Partner approval before the first live transmission. Describe how token consistency is achieved across independently deployed, site-local PPRL instances, without introducing a shared trust boundary outside the Healthcare Partner site. Describe how the solution preserves all source provenance metadata, permissions information, and ontology fields (e.g. SNOMED CT, LOINC, ICD-10, RxNorm, UCUM, etc.) without modification or loss, excluding authorized de-identification transformations performed under Section 4. The DSP will not create or standardize ontology mappings. Metadata must be additive, clearly identified, and each output value must be traceable to the source and authorized transformation. Describe how the solution consumes authoritative eligibility supplied by the Healthcare Partner and applies it before transmission; records the governing authorization or permission version for each dataset; distinguish cohort exclusions from permission exclusions; and apply revocations so that revoked records are absent from all subsequent refreshes. Describe how the solution generates full and incremental extracts; maintains stable patient tokens; creates unique snapshot and refresh IDs; supports idempotent reruns; identifies added, updated, deleted, merged, unmerged, corrected, and late-arriving records to the appropriate refresh cycle. Workflow Integrity & Processing Audit: maintain audit records for each stage; timestamp, stage ID, batch ID, record counts, outcome, and reconciliation status. Failed reconciliations or incomplete processing stages must halt transmission until resolved or authorized for reprocessing. Security Posture: Describe the ability to attest to HIPAA Security Rule compliance as a Business Associate; Security Audit Logging to generate SIEM-compatible security logs for authentication, administrative actions, configuration changes, and security events. Record timestamp, user/service account, action, resource, and outcome. Security logs must be protected against unauthorized modification or deletion, and logging must be continuous. Defense-in-Depth Encryption: TLS 1.3 where supported; TLS 1.2 minimum for all data in transit,; application-level encryption of output files and VM-level encryption. Attack Surface Minimization with no unnecessary ports, services, or network listeners by default. The only authorized external connection is the outbound TLS path to the Data COUNT Program Also see Section 1 regarding on-site operation of Leave Behind Technology; this section addresses the boundary for identifiable data processing. Describe how identifiable processing is confined to the Healthcare Partner�s VM and institutional trust boundary; only de-identified, tokenized output is transmitted for the Data COUNTS program; access is integrated with Healthcare Partner identity and access controls and is site-managed and logged; and the deployed solution does not include or permit contractor credentials, contractor remote-access pathways, or contractor remote-management capabilities. Describe supported performance at baseline, 2X, and 5X expected workloads and identify assumed data volumes, throughput, processing time, and Healthcare Partner CPU, memory, storage, network and staffing requirements. Describe how the solution can reliably package, transmit, reconcile, and retry deliveries to the TDB, including package, schema versioning, and error resolution. Business Information Requested Please provide information on the following: Details on which capabilities are able to be met Clarification on which features are commercial off-the-shelf (COTS), and which features would be considered minor modifications, and which features would be considered custom development features Billing model and pricing structure and any additional features and their subsequent costs Experience with successful implementation capabilities and list of healthcare partners Experience of similar work with Federal Government agencies Experience of similar work with industries or non-profit organizations Business size and status Response Format: Responses must be submitted by October 1, 2026, 3:00 Eastern Standard Time to DataCounts@nih.gov with the subject line Company Name RFI Response. Responses must be submitted in PDF or MS Word format. Organize the responses according to the numbered requests in this RFI. Questions may be submitted by September 15, 2026 to DataCounts@nih.gov. Government Follow-up The Government may contact respondents for clarification, additional information, or a capability demonstration. The Government is not obligated to contact any respondent. Disclaimer and Important Notes. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response to this notice. The Government reserves the right to use this information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed. Information provided will be used to assess tradeoffs and alternatives available for potential requirements and may lead to the development of a solicitation. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information or provide feedback to respondents with respect to the information submitted. Any solicitation resulting from the analysis of information obtained will be announced to the public. However, responses to this notice will not be considered responsive to solicitation. Confidentiality. No proprietary, classified, confidential or sensitive information should be included in a response. The Government reserves the right to use any non-proprietary technical information in any resulting solicitation. Attachments/Links include: www.nih.gov/data-counts Primary Point of Contact Susan Gregurick DATACOUNTS@nih.gov Christopher Ray Chris.ray@nih.gov

FEDERAL BUYER

Buyer and contracting office

View buyer page →
Department / agencyHEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tierNATIONAL INSTITUTES OF HEALTH
Contracting officeNATIONAL INSTITUTES OF HEALTH NIAID
Office addressBETHESDA, MD, 20892, USA

Public points of contact

PrimarySusan GregurickDATACOUNTS@nih.gov240.381.3566
SecondaryChris Raychris.ray@nih.gov2406273365

GOVBIDFIT SCREENING LENS

What deserves attention before you spend bid time

Decision support

These screening signals are generated from the public notice fields stored for this specific opportunity. They are not eligibility findings or predictions; they are prompts for a faster, more disciplined review of the official solicitation.

Market-research stage

This notice appears to be market research rather than a conventional bid invitation. A capability response, technical feedback or evidence of market interest may matter more than a price proposal at this stage.

Planning window available

The stored response date leaves more than ten days, but amendments and pre-response milestones can shorten the usable preparation window.

Eligibility gate recorded

No Set aside used is recorded as the set-aside or restriction. Confirm the bidding entity actually satisfies the applicable program and size requirements before investing proposal time.

Classification signal

PSC DA10 is the recorded classification. Use it as a screening clue, then compare the actual scope and deliverables rather than treating the code alone as proof of fit.

Notice history exists

GovBidFit stores 3 notices tied to this solicitation. Review the notice chain and official SAM.gov history because later postings can change dates, scope or instructions.

Official description available

GovBidFit has stored substantive notice text for this record, but attachments, clauses, amendments and Q&A can still contain requirements that are not visible in the description alone.

Public buyer contact available

The source data includes 2 public contracting contacts. Use the solicitation's stated communication rules and deadlines before contacting the buyer.

Questions to resolve next

Has SAM.gov posted an amendment or changed the response date, attachments or submission instructions since this GovBidFit snapshot was refreshed?Does the notice request a capability statement, technical response, questions, pricing input, or another specific market-research response?Are there question deadlines, site visits, registrations or internal approvals that occur before the final response date?Does the bidding entity hold the required current status for the recorded set-aside and the solicitation's assigned NAICS size standard?Can the business perform in Maryland at a sustainable cost after travel, mobilization, staffing, licensing and subcontractor requirements are considered?Which related notice or amendment currently controls the response instructions?

What this opportunity record tells you

SAM.gov identifies this as a sources sought from HEALTH AND HUMAN SERVICES, DEPARTMENT OF. The record was posted on September 1, 2026 and currently lists October 1, 2026 as the response deadline. GovBidFit keeps source facts separate from its matching guidance so you can see what comes from the federal notice.

The listed product or service classification is PSC DA10. The set-aside field is No Set aside used. These fields help narrow your search, but they do not replace the full solicitation, amendments, attachments, clauses or eligibility language on the official source.

Before deciding to bid

Read the complete official description and scope. Verify the exact response date, time and time zone on SAM.gov. Confirm NAICS/PSC and every set-aside eligibility requirement. Review attachments, amendments, Q&A and submission instructions. Check place of performance, staffing, insurance, bonding and execution requirements.
Source and trust

GovBidFit is independent and is not a U.S. government website. GovBidFit stores a structured mirror of SAM.gov public opportunity data in its own database and keeps the compact snapshot as a fallback. The official SAM.gov notice remains the controlling source. The official SAM.gov notice controls if anything here differs from the source or a later amendment.

Open the official SAM.gov notice →